IC元器件

SN65MLVD207DR

参考价格:¥10.21-¥10.97

Texas Instruments 接口 IC

SN65MLVD207DR 供应商

SN65MLVD207DR 属性参数

  • 制造商:Texas Instruments
  • 产品种类:LVDS 接口集成电路
  • 数据速率:200 Mbps
  • 工作电源电压:3.3 V
  • 最大工作温度:+ 85 C
  • 封装 / 箱体:SOIC-14
  • 封装:Reel
  • 最小工作温度:- 40 C
  • 安装风格:SMD/SMT
  • 工厂包装数量:2500
  • 电源电流:24 mA
  • Supply Voltage - Max:3.6 V
  • Supply Voltage - Min:3 V

产品特性

  • Low-Voltage Differential 30- Line Drivers and Receivers for Signaling Rates(1) Up to 200 Mbps
  • Type-1 Receivers Incorporate 25 mV of Hysteresis
  • Type-2 Receivers Provide an Offset (100 mV) Threshold to Detect Open-Circuit and Idle-Bus Conditions
  • Meets or Exceeds the M-LVDS Standard TIA/EIA-899 for Multipoint Data Interchange
  • Controlled Driver Output Voltage Transition Times for Improved Signal Quality
  • –1 V to 3.4 V Common-Mode Voltage Range Allows Data Transfer With 2 V of Ground Noise
  • Bus Pins High Impedance When Disabled or VCC ≤ 1.5 V
  • 100-Mbps Devices Available (SN65MLVD200A, 202A, 204A, 205A)
  • M-LVDS Bus Power Up/Down Glitch Free
  • APPLICATIONS Low-Power High-Speed Short-Reach Alternative to TIA/EIA-485 Backplane or Cabled Multipoint Data and Clock Transmission Cellular Base Stations Central-Office Switches Network Switches and Routers
  • Low-Power High-Speed Short-Reach Alternative to TIA/EIA-485
  • Backplane or Cabled Multipoint Data and Clock Transmission
  • Cellular Base Stations
  • Central-Office Switches
  • Network Switches and Routers

产品概述

The SN65MLVD201, 203, 206, and 207 are multipoint-low-voltage differential (M-LVDS) line drivers and receivers, which are optimized to operate at signaling rates up to 200 Mbps. All parts comply with the multipoint low-voltage differential signaling (M-LVDS) standard TIA/EIA-899. These circuits are similar to their TIA/EIA-644 standard compliant LVDS counterparts, with added features to address multipoint applications. The driver output has been designed to support multipoint buses presenting loads as low as 30 , and incorporates controlled transition times to allow for stubs off of the backbone transmission line.These devices have Type-1 and Type-2 receivers that detect the bus state with as little as 50 mV of differential input voltage over a common-mode voltage range of –1 V to 3.4 V. The Type-1 receivers exhibit 25 mV of differential input voltage hysteresis to prevent output oscillations with slowly changing signals or loss of input. Type-2 receivers include an offset threshold to provide a known output state under open-circuit, idle-bus, and other faults conditions. The devices are characterized for operation from –40°C to 85°C.